Нарушение
5 Окт 2026, Пн

Что такое испытание на герметичность вакуума?


Испытание на герметичность вакуума — это метод неразрушающего контроля, используемый для определения того, является ли герметичным запечатанный контейнер, упаковка, система или компонент, путём подвергания его воздействию вакуума и наблюдения за изменениями, указывающими на наличие утечки.


1. Основной принцип:


2.Detecting Leaks: If there is a leak in the item being tested:

Vacuum Decay Method: Air from the higher-pressure environment outside the test chamber will be drawn in through the leak. This causes the vacuum level inside the chamber to decrease (pressure rises) over time. The rate of pressure rise is measured and compared against predetermined acceptance criteria.

Helium Mass Spectrometry (for smaller leaks): The chamber (or sometimes the package interior) is filled with a tracer gas mixture containing helium. A powerful vacuum pump evacuates the chamber. A highly sensitive helium mass spectrometer detector is connected to the vacuum line. If a leak exists, helium is drawn into the item and then sucked out through the leak into the vacuum stream, where the detector identifies and quantifies it.



3.Purpose:

Detect Leaks: Identify the presence, location (sometimes), and sometimes quantify the size of leaks.

Ensure Seal Integrity: Verify that seals (lids, closures, welds, gaskets) are effective.

Confirm Barrier Properties: Ensure packaging materials or container walls are intact and impermeable to gases (especially oxygen and moisture vapor).

Guarantee Sterility/Safety: Prevent contamination (microbial, particulate, chemical) ingress or product egress.

Maintain Product Quality: Protect product shelf-life, efficacy, flavor, aroma, or performance.

Compliance: Meet regulatory standards and quality control requirements.


4.Key Components of the Test:

Test Chamber: Sealed enclosure to hold the test specimen(s).

Vacuum Pump: Creates the required vacuum level.

Pressure Sensors/Transducers: Precisely measure the vacuum/pressure level inside the chamber.

Control System & Software: Automates the test cycle (evacuation, stabilization, test time), acquires pressure data, calculates decay rates or leak rates, and compares results to pass/fail limits.

(For Tracer Gas Methods): Helium series resonance, mass spectrometer leak detector.


5.Industries & Applications:

Pharmaceuticals: Testing sterile vial/ampoule/syringe seals, blister packs, IV bags, medical device packaging (e.g., Tyvek® lids on trays/pouches).

Food & Beverage: Testing flexible and rigid packages (pouches, bottles, cans, trays with lidding film) for modified atmosphere packaging (MAP) or vacuum packaging.

Medical Devices: Verifying the integrity of implants, catheters, blood collection tubes, diagnostic kits, and sterile barrier systems.

Electronics: Testing hermetic seals on semiconductors, sensors, batteries, and components sensitive to moisture.

Automotive/Aerospace: Testing fuel systems, brake lines, air conditioning components, and sealed assemblies.

HVAC/Refrigeration: Checking coils, piping, and sealed systems for refrigerant leaks.

Packaging Suppliers: Validating packaging materials and seal processes.


6.Key Parameters:

Vacuum Level: The target pressure inside the chamber (e.g., -25 inHg, -28 kPa).

Stabilization Time: Time allowed after reaching the target vacuum for the system to settle before monitoring begins.

Test Time: The duration for which the pressure is monitored.

Acceptance Criteria: The maximum allowable pressure rise (decay) or the maximum allowable helium leak rate.


По сути:


Автор hvhipot