Troubleshooting method of high voltage generator

Troubleshooting Methods of DC High Voltage Generator

1. Failure phenomenon: After the power switch is turned on, the indicator light and the meter head are not bright, and the fan does not rotate

Reason: the power cord is open, or the power fuse is blown

Treatment method: replace the power cord and insurance

2. Trouble phenomenon: After the machine is turned on, the high-voltage break button light is on, but the high-voltage switch button does not light up when pressed

Reason: adjust the voltage potentiometer knob is not reset

Treatment method: reset the voltage adjustment potentiometer knob to zero again

3. Trouble phenomenon: Press the high-voltage switch button, the indicator light is on, but the high-voltage switch indicator does not go off, release the high-voltage switch button, the high-voltage switch indicator light

Reason: The internal protection circuit of the host has acted (overvoltage, overcurrent or power protection)

Treatment method: adjust the fixed value of the overvoltage setting dial code to an appropriate value, and then restart the device

4. Trouble phenomenon: After pressing the high-voltage switch button, the voltage is boosted, the high-voltage break indicator light is on, and the high-voltage is disconnected.

Reason: high voltage output short circuit

Treatment method: check whether the tested product is short-circuited

5. Failure phenomenon: During the boosting process, the high-voltage break indicator light is on and the high-voltage disconnect

Reason: Discharge or breakdown of the tested product causes overcurrent protection to act

Solution: Check the tested product and restart the device

By hvhipot