Five characteristics of series resonant devices

The complete set of frequency conversion series resonance test equipment consists of a frequency conversion power supply, excitation transformer, high-voltage reactor, and capacitive voltage divider; The complete set of frequency conversion series resonance test equipment adopts the method of adjusting the frequency of the power supply to achieve resonance between the reactor and the tested capacitor, and obtain high voltage and high current on the tested object. The capacitor and reactor of the sample are connected in series resonance, and the voltage divider is connected in parallel with the sample. The resonant voltage is measured using a frequency conversion series resonance test set and an overvoltage protection signal is issued; The excitation transformer couples the FM power output to the series resonant circuit, providing excitation power for series resonance.

The complete set of frequency conversion series resonance test equipment has a high degree of automation, small size, and light weight. The weight of each unit in the complete set of equipment shall not exceed 40kg, and it is suitable for on-site handling. The reactor adopts dry epoxy casting, which is reliable in operation, easy to transport, and does not require lifting for on-site testing. Installation testing can be carried out manually. The frequency converter series resonance testing equipment is widely used in industries such as power, metallurgy, petroleum, and chemical.

Functional characteristics of the complete set of frequency conversion series resonance test equipment:

1. High stability and reliability, the system uses imported power components as the core of power conversion.

2. The automatic tuning function is powerful. When the variable frequency series resonance testing system is automatically tuned, the frequency scanning curve is displayed between 30 Hz and 300 Hz.

3. Supports multiple testing modes, including “automatic tuning and manual voltage adjustment”, “automatic tuning and automatic voltage adjustment”, and “manual tuning and manual voltage adjustment”.

4. The system has a user-friendly human-machine interface, with test parameter settings, test control, and equivalent screen display of test results, which is intuitive and clear. It also has automatic timing and operation prompt functions. The complete set of variable frequency series resonance test equipment adopts full touch screen operation and display, and has the function of saving and querying test data.

5. The protection function is complete, and the complete set of frequency conversion series resonance test equipment has functions such as zero position protection, overcurrent protection, overvoltage protection, and flashover protection, ensuring the reliability of the system.