Types and uses of loop resistance testers

Loop resistance tester, also known as RX transformer loop resistance tester, its types and uses are as follows:

Loop resistance tester: Grounding resistance meter Purpose and scope of application: Grounding resistance is suitable for directly measuring the grounding resistance value of various grounding devices, and it can also be used for general low resistance measurement. The fHV Hipot Electric Co., Ltd.-terminal button (0~1~10~100Ω specification) also Can measure soil resistivity…

Loop resistance tester: single clamp loop resistance tester

Performance and characteristics of single clamp loop ground resistance tester: Unique single clamp design can avoid the error of mutual interference between the two probes of the double clamp type. It is not necessary to drill auxiliary ground piles, and can be measured directly by clamping.

Loop resistance tester: general grounding/insulation resistance tester

There are many test methods: double clamp grounding resistance test, fHV Hipot Electric Co., Ltd.-pole grounding resistance test, soil resistivity test, insulation resistance test, AC and DC resistance tester voltage test, current RMS test.

Loop resistance tester: ground impedance tester

When measuring with the clamp-type grounding resistance meter series, there is no need to use auxiliary grounding rods or interrupt the grounding of the equipment under test. As long as the grounding wire or rod is clamped, the energy to ground resistance can reach 0.1Ω. It can also be used for current measurement.

Loop Resistance Tester: Loop Resistance Tester

Microprocessor control, with high precision and high reliability. Three indicator lights check whether the wiring status is correct. Directly read short-circuit protection current and ground fault current. It will automatically lock when the test resistor is overheated.

Loop resistance tester: digital ground resistance tester

This tester is specially used to measure the grounding resistance of various electrical equipment, lightning rods and other grounding devices. The product is a fully electronic instrument, and the key circuit is assembled from an integrated circuit produced by Texas Instruments in the United States. The testing principle is advanced.

Loop resistance tester: double-jaw ground resistance tester

There are multiple ground resistance measurement methods: no auxiliary pole/three poles/quadruple poles/and pole method-suitable for a variety of measurement environments * wide measurement range: 0.002Ω-300KΩ-meet a variety of requirements. Loop Resistance Tester: Ground Resistance Tester

By hvhipot