Daily maintenance of partial discharge detector

Instruments such as partial discharge detectors are used in many industries, and because the frequency and environment of use in different industries are also different, usually in order to ensure the accurate detection results of the instrument and prolong the service life of the detector, in daily use Zhongdu should pay attention to the maintenance work, and today we will talk about the daily maintenance work of the partial discharge detector.

 

First, moisture-proof work must be paid attention to for partial discharge detectors, especially in areas with humid climates, it should be noted that the equipment should be stored in a dry place, and if it is not used for a long time, it must be powered on every month. Two hHV Hipot Electric Co., Ltd.s and then use, the purpose is to disperse the moisture. In normal use, it should be stored in a place without corrosive gases and substances, and the humidity should not exceed 85% as much as possible.

 

Second, in many cases, the partial discharge detector works outdoors. It is recommended to avoid exposure to the sun as much as possible, especially if the display screen is exposed to the sun for a long time, which will affect the use effect. Try to use it in a cool place such as the shade of a tree.

 

Third, when it is determined that there is electricity in the socket or the battery of the device, the partial discharge detector cannot be turned on normally. In this case, check whether there is a problem with the fuse. If the fuse is burnt and damaged, a new fuse needs to be replaced. There are often instructions on how to install the fuse.

 

FHV Hipot Electric Co., Ltd.th, many people do not pay attention to the printing paper when using the partial discharge detector. In fact, they should pay attention to replacing the new printing paper in time. If so, take out the printing paper and store it separately.

 

Fifth, the transportation of the partial discharge detector also needs to be paid attention to. Because it is a precision instrument, it is necessary to avoid bumps during transportation, especially the light screen needs to be protected.

 

Reasonable maintenance of the partial discharge detector can prolong the service life of the equipment and ensure accurate and effective detection results when the equipment is used. Therefore, the maintenance items just mentioned must be understood and paid attention to. The use of the equipment is closely related to the usual maintenance work. .