Principle Analysis of DC Resistance Tester

Insulation resistance refers to the resistance between two parts of conductors separated by insulating materials, and the insulation resistance tester is an instrument used to measure the insulation resistance. In order to ensure the safety of electrical equipment operation, it should deal with different polarities (different phases). The insulation resistance between the conductors or between the conductor and the shell puts forward a requirement. As an electrical appliance manufacturer, Wuhan Boshi Electric Co., Ltd. must conduct an insulation resistance test under a certain voltage before leaving the factory to ensure the equipment’s performance. The personal safety of personnel working normally and using the equipment. 

Many electrical equipment must be regularly tested for insulation resistance during use. For example, during the annual yellow plum season and thunderstorm weather, various electrical equipment of various enterprises, especially high-voltage equipment, will have varying degrees of moisture or partial damage, which will cause electrical damage. The reduction of the insulation resistance of the equipment directly threatens the safe operation of electrical equipment and the personal safety of staff. In order to prevent accidents, various preventive tests must be carried out on electrical equipment on a regular basis. Another example is the safety requirements of household appliances: basic The insulation is 2MQ; the reinforced insulation is 7MQ, which is for the normal operation of electrical equipment and the personal safety of the staff. 

Therefore, it is particularly important to understand the insulation characteristics of the equipment. The factors that affect the measured value of the insulation resistance are: temperature, humidity, measurement voltage and time of action, residual charge in the winding and the surface condition of the insulation, etc. By measuring the insulation resistance of electrical equipment, The following goals can be achieved:  

(1) Understand the insulation performance of the insulation structure. A reasonable insulation structure (or insulation system) composed of high-quality insulation materials should have good insulation performance and high insulation resistance;  

(2) Understand the quality of insulation treatment of electrical products. If the insulation treatment of electrical products is not good, the insulation performance will be significantly reduced;  

(3) Understand the damp and contamination of insulation. When the insulation of electrical equipment is damp and contaminated, the insulation resistance will usually decrease significantly;  

(4) Check whether the insulation can withstand the withstand voltage test. If the withstand voltage test is performed when the insulation resistance of the electrical equipment is lower than a certain limit, a larger test current will be generated, which will cause thermal breakdown and damage the insulation of the electrical equipment. Therefore, usually various test standards stipulate that the insulation resistance should be measured before the withstand voltage test. 

It can be seen that the size of the insulation resistance can often sensitively reflect the insulation situation, and can effectively discover the general damp, local severe damp and penetrating defects of the equipment. Therefore, measuring the insulation resistance is one of the important means to understand the insulation of the equipment, and it is insulation prevention. An indispensable item in the sex test.

Avatar photo

By hvhipot