20kV/10kA Impulse Combination Wave Test System: A Comprehensive Technical Solution by HVHIPOT

Introduction

In the realm of high-voltage testing, the 20kV/10kA Impulse Combination Wave Test System stands as a critical tool for evaluating the dielectric strength and surge resistance of electrical equipment. This system generates standardized lightning and switching impulses to simulate real-world transient overvoltage conditions. HVHIPOT, a leader in high-voltage test solutions, offers an advanced technical solution that combines precision, safety, and reliability for industrial applications.

Key Components of the Test System

1. Impulse Voltage Generator

The core of the system is a multi-stage Marx generator capable of producing 20kV impulses with a rise time of 1.2μs and a decay time of 50μs (for lightning impulses) or 250μs (for switching impulses). HVHIPOT’s design ensures minimal waveform oscillations (<±3%) and high energy efficiency.

2. Current Surge Module

The 10kA current surge component delivers an 8/20μs current wave, critical for testing surge protective devices (SPDs). The integrated current measurement system achieves ±1% accuracy using Rogowski coils or shunt resistors.

3. Control and Monitoring Unit

A touchscreen HMI allows operators to:

  • Set waveform parameters (front time, tail time, polarity)
  • Automate test sequences per IEC 61000-4-5
  • Monitor real-time waveforms via built-in oscilloscope

Technical Advantages

Precision Waveform Generation

HVHIPOT’s proprietary damping circuit technology ensures compliance with IEC 60060-1 standards, achieving:

  • Lightning impulse: 1.2/50μs ±10%
  • Switching impulse: 250/2500μs ±20%
  • Current impulse: 8/20μs ±10%

Enhanced Safety Features

The system incorporates:

  • Automatic discharge circuits
  • Grounding interlocks
  • Remote emergency stop

Scalability

Modular design allows voltage/current upgrades up to 100kV/100kA for future-proofing.

Applications

This system is indispensable for testing:

  • Power transformers
  • Insulators and bushings
  • Surge arresters
  • Military/aerospace components

HVHIPOT’s Implementation Methodology

  1. Site Assessment: Evaluate facility requirements (space, power supply, grounding)
  2. System Configuration: Customize waveform libraries and test protocols
  3. Validation Testing: Perform calibration using reference dividers
  4. Training: 3-day onsite operator certification

HVHIPOT’s 20kV/10kA Impulse Combination Wave Test System delivers unmatched precision for high-voltage immunity testing. With its robust design and compliance with international standards, it serves as a turnkey solution for laboratories and manufacturers. Explore the full technical specifications to understand how this system can enhance your testing capabilities.

Avatar photo

By hvhipot